enLanguage

30kW Bidirectional Storage Inverter

30kW Bidirectional Storage Inverter
Details:
The 30kW Bidirectional Storage Inverter is built for modular BESS integration, providing reliable energy conversion and flexible control for commercial storage and backup power applications.

●30kW Bidirectional Power Conversion for BESS
●150–750V Wide Battery Voltage Range
●19-Inch Rack-Compatible Compact Design
●Scalable AC and DC Parallel Operation
●Flexible Grid-Tied and Off-Grid Operation
Send Inquiry
Download
Description
Technical Parameters

30kW Bidirectional Storage Inverter

The 30kW Bidirectional Storage Inverter serves as the power conversion core of modular battery energy storage systems, managing energy exchange between batteries, AC loads, and the grid.

Built for commercial energy storage, backup power, and distributed energy projects, this compact energy storage inverter gives system integrators a flexible foundation for BESS design. It supports varied operating requirements and project layouts, while leaving room for future expansion as power and energy needs evolve.

30kW Bidirectional Storage Inverter

 

Key Features

 

Core features for flexible BESS integration and expansion.

Bidirectional Energy Conversion

Enables controlled charging and discharging between the battery system and AC side, supporting flexible power flow for commercial energy storage, backup power, and microgrid operation.

Wide Battery Compatibility

The 150–750V battery range supports flexible system matching, while compatibility with lithium, lead-acid, sodium-ion, and flywheel storage broadens project configuration options.

Compact Rack-Mounted Integration

The 19-inch rack-compatible design simplifies installation inside BESS cabinets, helping system integrators reduce space requirements and streamline equipment layout.

Scalable Parallel Expansion

Parallel operation on both the AC and DC sides supports modular capacity growth. Up to 10 units can operate in parallel for larger off-grid power requirements.

Flexible Solar and Backup Options

An optional PV charger supports DC-coupled solar-plus-storage systems, while an optional smart transfer switch enables automatic backup operation when required.

Efficient and Connected Operation

With peak efficiency up to 97.3% and CAN, RS485, Ethernet, and WiFi communication, the bidirectional inverter supports efficient operation and flexible system communication.

 

Specification

Battery Side  
Charging and Discharging voltage range 150V-750V (350V-750V @full load)
Rated Power 30kW
Maximum Power 33kW
Maximum Charging and Discharging Current 90A
Battery Switch-off Mode Relay
Over Voltage Protection Software Protection
Over Current Protection Software Protection & DC Fuse
DC Bus Side  
Rated Power 45kW
Input Voltage Range 700V-830V
Maximum Input Current 32.5A*2
AC Output  
Rated Output Power Grid-tied/Off-grid: 30kW
Maximum Apparent Power Grid-tied/Off-grid: 33kVA
Maximum Active Power Grid-tied/Off-grid: 33kW
Rated Grid Voltage Grid-tied: 3P3W+PE, 480 (±15%) Vac
Off-grid: 3P3W+PE, 480 (±5% configurable) Vac
Rated frequency Grid-tied: 60 (±2.5) Hz
Off-grid: 60 (±5 configurable) Hz
Power Factor

Grid-tied/Off-grid:

Listed: 0.8~1 leading or lagging

Actual:0.1~1 leading or lagging

THDi <3%
Overload Capacity

110%~120%, 10 min          120%~130%, 1 min

130%~150%, 200ms          >150%, 100ms

Off-grid & Parallel  
External transformer Droop control parallel/Communication parallel: Yes
Maximum number of parallel Droop control parallel/Communication parallel: 10
Total length of parallel lines

Droop control parallel: No limit

Communication parallel: 7m

General Specification  
Peak Efficiency 97.3%
CEC Measured Efficiency 95.5%
Communication Port CAN/RS485/Ethernet/WIFI
Dimension (WHD)

440x173x550mm

440x173x596mm (including handles)

Cooling Forced Air Cooling
Weight 33kg
Topology Non-isolation
Operation Altitude 3000m (>3000m derating)
Operation Environment Contamination Level ≤2
Temperature & Humidity -30℃~60℃ (>45℃ derating) & 0-95%
Noise ≤75dB
IP Rating IP20
Grid-tied Standard IEEE1547;UL1741SA;RULE 21
Safety Certification UL1741; UL9540A
EMC Standard FCC

 

30kW Battery Power Conversion System for Modular BESS

 

 

In battery energy storage projects, a bidirectional storage inverter may also be described as a bidirectional battery inverter, energy storage PCS, BESS inverter, or Power Conversion System (PCS). Its role is to control two-way AC/DC power conversion between the battery system and the AC electrical network.

 

This specific 30kW PCS is defined by a 150–750V battery operating window, 30kW rated charging/discharging power, a 480Vac three-phase AC interface, grid-tied and off-grid operating specifications, and modular parallel capability. Those electrical boundaries are more useful for product selection than broad application labels because they determine whether the inverter can fit the battery voltage, AC bus, cabinet layout, and control architecture of a particular BESS.

 

Bidirectional Power Flow

 

The inverter operates in both charging and discharging directions.

On the battery side it manages DC power within the specified voltage/current envelope;

on the AC side it interfaces with a 3P3W+PE, 480Vac system.

 

product-1204-150

Charging Direction

AC power is converted to DC for battery charging. Charge power and current must remain within the battery system limits and the inverter's 30kW / 90A operating envelope.

Discharging Direction

Stored DC energy is converted to three-phase AC. The inverter executes the active-power command within its output, voltage, frequency, power-factor, and overload limits.

Control Boundary

The PCS performs the conversion; the surrounding battery, BMS, EMS or site controller provides operating limits, permissions, scheduling, and project-level strategy.

 

30kW System Integration

 

30kW Modular Power Conversion Block

The 30kW rating describes instantaneous conversion power, not stored energy capacity. Battery kWh determines how much energy is available, while PCS kW determines how quickly that energy can be charged or discharged within the supported voltage and current limits.

01

150–750V Battery-Side Matching

The charging/discharging window spans 150–750V, while full-load operation is specified from 350–750V. Matching a compatible high-voltage battery system therefore requires checking the actual pack voltage over SOC, the BMS current limits, and the intended operating power-not only the nominal battery voltage.

02

480Vac Three-Phase AC Integration

The AC side is specified as 3P3W+PE, 480Vac and 60Hz. Grid-tied voltage is listed at 480Vac ±15%; off-grid voltage is 480Vac ±5% configurable. This makes the unit a 480V three-phase battery inverter for systems designed around that AC platform.

03

Power Quality and Reactive-Power Range

For the AC interface, the specification lists THDi below 3% and leading/lagging power-factor capability. These parameters matter when the 30kW PCS is integrated into a facility AC bus and must operate within the site's electrical and interconnection requirements.

04

 

Parallel PCS Architecture

Scale the 30kW PCS Building Block Up to 10 Parallel Units.In applicable off-grid configurations,

the system supports the parallel operation of up to ten units using either

droop control or communication-based parallel control. There is no need to use different converter specifications for different capacity ratings.

 

product-1148-271

Droop Control vs Communication Parallel

Parameter Droop Control Parallel Communication Parallel
External Transformer Yes Yes
Maximum Parallel Units 10 10
Total Length of Parallel Lines No limit 7m

 

 

Mechanical Integration

19-Inch Rack-Mounted PCS for BESS Cabinet Integration

 

The mechanical format is one of this model's most specific deployment characteristics. The 440mm-wide chassis, rack-compatible design, forced-air cooling and IP20 rating indicate a PCS intended to be integrated inside a larger controlled electrical enclosure or BESS cabinet.

  • Chassis Dimension:440 × 173 × 550mm
  • With Handles:440 × 173 × 596mm
  • Weight:33kg
  • Cooling:Forced Air
  • IP Rating:IP20
  • Topology:Non-isolation

Cabinet-level design: rack compatibility does not replace enclosure engineering. Airflow, service clearance, ambient temperature, contamination level, cable routing, protection, and cabinet IP rating remain part of the complete BESS design.

 

PV Charger and Smart Transfer Switch Integration

We offer a variety of transmission components

 

DC-Coupled PV + Battery Architecture

An optional PV charger can introduce PV generation on the DC side of the storage architecture. In this configuration, the battery PCS continues to manage battery-to-AC bidirectional conversion while the PV charger manages the PV-side DC conversion. This is a more precise way to describe DC-coupled battery storage than labeling the base product as a hybrid inverter.

Grid / Backup Transfer Architecture

The optional smart transfer switch provides the switching layer required by backup-oriented system designs, while the PCS remains responsible for AC/DC power conversion. Separating the switching function from the PCS function clarifies where transfer, isolation, protection and power conversion occur in the complete electrical architecture.

30kW Bidirectional Storage Inverter FAQ

Q: What does the 30kW rating mean in a battery energy storage system?

A: The 30kW rating is the inverter's rated power-conversion capability. It describes how much power the PCS can process at a given time; it does not describe the battery's energy capacity in kWh. Battery capacity and PCS power should therefore be sized as separate but related BESS parameters.

Q: Can this PCS operate at full 30kW across the entire 150–750V battery range?

A: The supplied specification lists a 150–750V charging/discharging voltage range and specifically states 350–750V at full load. Battery pack voltage over the usable SOC range should therefore be checked against the required operating power.

Q: Is this a 480V three-phase battery inverter?

A: Yes. The AC specification lists 3P3W+PE, 480Vac for both grid-tied and off-grid operation. Grid-tied voltage tolerance is listed as ±15%; off-grid voltage is listed as ±5% configurable.

Q: How many 30kW PCS units can operate in parallel?

A: Applicable to up to 10 parallel units arranged using droop control or communication-based parallel operation in off-grid configurations. Before accounting for project-specific system limitations, ten 30 kW modules represent a nominal module rating of 300 kW.

Q: What is the difference between droop-control and communication-parallel configurations on this product?

A: Droop-control parallel is shown with no total line-length limit, while communication parallel is listed at 7m. The final project should follow the selected control and wiring architecture.

Q: What battery chemistries can be integrated with the inverter?

A: The product information lists lithium, lead-acid, sodium-ion, and flywheel storage. Compatibility should still be verified against battery voltage, current, BMS limits, protection logic, communications and operating commands rather than battery chemistry alone.

Q: What communication interfaces are available for BMS and EMS integration?

A: The listed communication ports are CAN, RS485, Ethernet and WiFi. Integration engineering should confirm the exact protocol implementation and required data points for the selected battery management system and energy management system.

Q: Is the 30kW unit a hybrid solar inverter?

A: The base product is described as a bidirectional storage inverter / battery PCS. The product information lists an optional PV charger for DC-coupled solar-plus-storage configurations. That is different from assuming dedicated PV MPPT input is integrated into the standard PCS itself.

Q: What should be considered when installing the PCS inside a BESS cabinet?

A: The product is 19-inch rack compatible, weighs 33kg, uses forced-air cooling and is rated IP20. Cabinet integration should account for mechanical support, airflow, service access, cable routing, ambient temperature, contamination level, protection and the enclosure rating required by the installation.

 

 

modular-1

Discuss Your 30kW PCS Requirement

Share your battery voltage, required PCS power, grid configuration, and project requirements. We can use these details to confirm whether the 30kW Bidirectional Storage Inverter matches your BESS design.

 

 

 

 

 

Hot Tags: Bidirectional Storage Inverter, 30kW Bidirectional Storage Inverter, 30kW PCS, Bidirectional Battery Inverter, Energy Storage PCS, BESS Inverter, 480V Battery Inverter, Three Phase Battery Inverter, Parallel PCS, Rack Mounted PCS

Send Inquiry
Smarter Energy, Stronger Operations.

Polinovel delivers high-performance energy storage solutions to strengthen your operations against power disruptions, lower electricity costs through intelligent peak management, and deliver sustainable, future-ready power.